{"id":125,"date":"2026-06-19T15:30:51","date_gmt":"2026-06-19T15:30:51","guid":{"rendered":"https:\/\/biotech.deusto.es\/?page_id=125"},"modified":"2026-06-23T15:55:35","modified_gmt":"2026-06-23T15:55:35","slug":"human-physiology","status":"publish","type":"page","link":"https:\/\/biotech.deusto.es\/?page_id=125","title":{"rendered":"Human physiology"},"content":{"rendered":"\n<h2 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-1\"><strong>PowerLab 26T + Human Physiology Kit<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-2\">\n<li class=\"has-black-color has-text-color has-link-color wp-elements-3\"><strong>Available Quantity:<\/strong> 5 units<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-4\"><strong>Official Supplier:<\/strong> ADINSTRUMENTS<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/www.adinstruments.com\/products\/powerlab\/26-series\"><img decoding=\"async\" src=\"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280\" alt=\"\" style=\"width:521px;height:auto\"\/><\/a><\/figure>\n<\/div>\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-5 wp-block-paragraph\"><strong>Subjects:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-black-color has-text-color has-link-color wp-elements-6\">Systems and Signals for Biomedical Environments<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-7\">TFG<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-8\">Technical Description<\/h5>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-9 wp-block-paragraph\">The PowerLab 26T is an integrated data acquisition (DAQ) system designed for high-resolution recording and analysis of human physiological signals in both educational and advanced research settings. In biomedical engineering, it serves as a central platform for real-time monitoring of biopotentials and physiological phenomena. When combined with the Human Physiology Kit, the system allows students and researchers to safely acquire, amplify, and digitize a wide range of biological signals directly from the human body, bridging the gap between physiological events and digital signal processing algorithms.<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-10\">Technical Features &amp; Capabilities<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-black-color has-text-color has-link-color wp-elements-11\"><strong>Multi-Signal Acquisition:<\/strong> Simultaneously records essential human physiological inputs, including Electrocardiography (ECG), Electromyography (EMG), Electroencephalography (EEG), respiratory airflow, finger pulse, and galvanic skin response (GSR).<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-12\"><strong>Safe Human Isolation:<\/strong> Features built-in, bio-amplifier isolation certified for human subject safety, preventing electrical hazards during live experimentation.<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-13\"><strong>Signal Conditioning:<\/strong> High-performance analog-to-digital converters and integrated hardware filters that ensure clean, low-noise signal outputs.<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-14\"><strong>Data Export:<\/strong> Facilitates seamless raw data extraction for advanced mathematical modeling, digital filtering, and algorithmic analysis.<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-15\">Software &amp; Integration<\/h5>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-16\">\n<li class=\"has-black-color has-text-color has-link-color wp-elements-17\"><strong>Compatible Software:<\/strong> LabChart (Proprietary software) &amp; MATLAB.<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-18\"><strong>Functionality:<\/strong> Fully integrated with LabChart software for real-time visualization, automated analysis, and computational extraction of physiological parameters. Data streams can also be exported to MATLAB for custom digital signal processing and advanced biomedical research.<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-black-background-color has-background wp-element-button\" href=\"https:\/\/www.adinstruments.com\/support\/software?srsltid=AfmBOoqlnCivhrZsvZlnpxQaNP7Prlc1Ho7ebeKLovXU-zOKfZisO2K8\">Labchart<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-black-background-color has-background wp-element-button\" href=\"http:\/\/la.mathworks.com\/help\/install\/ug\/install-products-with-internet-connection.html\">Matlab<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-19\">HE Techpatient Cardio (ECG Simulator)<\/h4>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-20\">\n<li><strong>Available Quantity:<\/strong> 15 units<\/li>\n\n\n\n<li><strong>Official Supplier:<\/strong> METRON MEDICAL SUPPLIES, S.L.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.medicalexpo.es\/prod\/he-instruments-llc-121466.html\"><img decoding=\"async\" src=\"https:\/\/img.medicalexpo.es\/images_me\/photo-mg\/121466-17272736.webp\" alt=\"\"\/><\/a><\/figure>\n<\/div>\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-21 wp-block-paragraph\"><strong>Subjects:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-black-color has-text-color has-link-color wp-elements-22\">Systems and Signals for Biomedical Environments<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-23\">Biomedical Systems and Prototyping<\/li>\n\n\n\n<li class=\"has-black-color has-text-color has-link-color wp-elements-24\">TFG<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-25\">Technical Description<\/h5>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-26 wp-block-paragraph\">The HE Techpatient Cardio is a specialized, high-fidelity electrocardiogram (ECG) and physiological signal simulator. Within the laboratory ecosystem, it acts as a standardized, reliable calibration and testing source for biomedical instrumentation. Instead of connecting human subjects during preliminary hardware design phases, this device generates precise, repeatable pathological and normal cardiac waveforms. It is critical for validating the performance, accuracy, and filtering capabilities of student-built ECG amplifiers, patient monitors, and automated diagnostic algorithms.<\/p>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-27\">Technical Features &amp; Capabilities<\/h5>\n\n\n\n<ul class=\"wp-block-list has-black-color has-text-color has-link-color wp-elements-28\">\n<li><strong>Waveform Generation:<\/strong> Outputs a comprehensive library of normal sinus rhythms and various cardiac arrhythmias (tachycardia, bradycardia, blocks, etc.) for testing diagnostic devices.<\/li>\n\n\n\n<li><strong>Standard Lead Outputs:<\/strong> Provides realistic electrical microvolt outputs through physical snap connectors matching standard clinical ECG patient cables.<\/li>\n\n\n\n<li><strong>Equipment Calibration:<\/strong> Used as a reference standard to test the sensitivity, frequency response, and alarm triggers of patient monitoring instrumentation.<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading has-black-color has-text-color has-link-color wp-elements-29\">Software &amp; Integration<\/h5>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-30 wp-block-paragraph\">This equipment operates as a hardware-centric, standalone instrument using native embedded firmware. For technical documentation, hardware support, and compatibility specifications, resources can be accessed via the official supplier platform.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>PowerLab 26T + Human Physiology Kit Subjects: Technical Description The PowerLab 26T is an integrated data acquisition (DAQ) system designed for high-resolution recording and analysis of human physiological signals in both educational and advanced research settings. In biomedical engineering, it serves as a central platform for real-time monitoring of biopotentials and physiological phenomena. When combined [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-125","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Human physiology - | BioTech Lab<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/biotech.deusto.es\/?page_id=125\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Human physiology - | BioTech Lab\" \/>\n<meta property=\"og:description\" content=\"PowerLab 26T + Human Physiology Kit Subjects: Technical Description The PowerLab 26T is an integrated data acquisition (DAQ) system designed for high-resolution recording and analysis of human physiological signals in both educational and advanced research settings. In biomedical engineering, it serves as a central platform for real-time monitoring of biopotentials and physiological phenomena. When combined [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/biotech.deusto.es\/?page_id=125\" \/>\n<meta property=\"og:site_name\" content=\"| BioTech Lab\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-23T15:55:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125\",\"url\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125\",\"name\":\"Human physiology - | BioTech Lab\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/linahp.com\\\/cdn\\\/shop\\\/files\\\/PL26T04.webp?v=1749571715&amp;width=1280\",\"datePublished\":\"2026-06-19T15:30:51+00:00\",\"dateModified\":\"2026-06-23T15:55:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125#primaryimage\",\"url\":\"https:\\\/\\\/linahp.com\\\/cdn\\\/shop\\\/files\\\/PL26T04.webp?v=1749571715&amp;width=1280\",\"contentUrl\":\"https:\\\/\\\/linahp.com\\\/cdn\\\/shop\\\/files\\\/PL26T04.webp?v=1749571715&amp;width=1280\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/?page_id=125#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\\\/\\\/biotech.deusto.es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Human physiology\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#website\",\"url\":\"https:\\\/\\\/biotech.deusto.es\\\/\",\"name\":\"| BioTech Lab\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/biotech.deusto.es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#organization\",\"name\":\"| BioTech Lab\",\"url\":\"https:\\\/\\\/biotech.deusto.es\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/biotech.deusto.es\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo-deusto-simple.png\",\"contentUrl\":\"https:\\\/\\\/biotech.deusto.es\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/logo-deusto-simple.png\",\"width\":451,\"height\":632,\"caption\":\"|     BioTech Lab\"},\"image\":{\"@id\":\"https:\\\/\\\/biotech.deusto.es\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Human physiology - | BioTech Lab","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/biotech.deusto.es\/?page_id=125","og_locale":"es_ES","og_type":"article","og_title":"Human physiology - | BioTech Lab","og_description":"PowerLab 26T + Human Physiology Kit Subjects: Technical Description The PowerLab 26T is an integrated data acquisition (DAQ) system designed for high-resolution recording and analysis of human physiological signals in both educational and advanced research settings. In biomedical engineering, it serves as a central platform for real-time monitoring of biopotentials and physiological phenomena. When combined [&hellip;]","og_url":"https:\/\/biotech.deusto.es\/?page_id=125","og_site_name":"| BioTech Lab","article_modified_time":"2026-06-23T15:55:35+00:00","og_image":[{"url":"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/biotech.deusto.es\/?page_id=125","url":"https:\/\/biotech.deusto.es\/?page_id=125","name":"Human physiology - | BioTech Lab","isPartOf":{"@id":"https:\/\/biotech.deusto.es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/biotech.deusto.es\/?page_id=125#primaryimage"},"image":{"@id":"https:\/\/biotech.deusto.es\/?page_id=125#primaryimage"},"thumbnailUrl":"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280","datePublished":"2026-06-19T15:30:51+00:00","dateModified":"2026-06-23T15:55:35+00:00","breadcrumb":{"@id":"https:\/\/biotech.deusto.es\/?page_id=125#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/biotech.deusto.es\/?page_id=125"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/biotech.deusto.es\/?page_id=125#primaryimage","url":"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280","contentUrl":"https:\/\/linahp.com\/cdn\/shop\/files\/PL26T04.webp?v=1749571715&amp;width=1280"},{"@type":"BreadcrumbList","@id":"https:\/\/biotech.deusto.es\/?page_id=125#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/biotech.deusto.es\/"},{"@type":"ListItem","position":2,"name":"Human physiology"}]},{"@type":"WebSite","@id":"https:\/\/biotech.deusto.es\/#website","url":"https:\/\/biotech.deusto.es\/","name":"| BioTech Lab","description":"","publisher":{"@id":"https:\/\/biotech.deusto.es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/biotech.deusto.es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/biotech.deusto.es\/#organization","name":"| BioTech Lab","url":"https:\/\/biotech.deusto.es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/biotech.deusto.es\/#\/schema\/logo\/image\/","url":"https:\/\/biotech.deusto.es\/wp-content\/uploads\/2026\/04\/logo-deusto-simple.png","contentUrl":"https:\/\/biotech.deusto.es\/wp-content\/uploads\/2026\/04\/logo-deusto-simple.png","width":451,"height":632,"caption":"|     BioTech Lab"},"image":{"@id":"https:\/\/biotech.deusto.es\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/pages\/125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=125"}],"version-history":[{"count":17,"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/pages\/125\/revisions"}],"predecessor-version":[{"id":231,"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=\/wp\/v2\/pages\/125\/revisions\/231"}],"wp:attachment":[{"href":"https:\/\/biotech.deusto.es\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}